The client was required to submit detailed design drawings in accordance with the SEQ W&S D&C Code, certified by a Registered Professional Engineer Queensland (RPEQ) for a property in Mermaid Beach.

JJR Involvement :

CCTV survey of the existing sewer pipeline was obtained to confirm that the condition of the existing system could facilitate additional load.

The CCTV survey outcomes and deliverables included:

  • Sewer line was in good condition;
  • Hydraulic calculations were developed confirming that the existing sewer would have sufficient capacity for an additional housing connection; and
  • Drawings were produced indicating a maintenance hole at the intersection of the proposed house drain sewer connection if connecting from the sewer in the road.